Brand Name : VICTOR

Model Number : VICTOR 04S

Certification : CE

Place of Origin : CHINA

MOQ : 10pcs

Price : USD115/pc

Payment Terms : T/T, Western Union, L/C, Paypal

Supply Ability : 1000pcs available

Delivery Time : 5 to 30 days

Packaging Details : 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10KG/carton

Color : Blue and Black

Size : 180*90*47mm

Product Name : Voltage/mA Source

Model No. : VICTOR 04S

Material : Plastic, metal, silica gel

Packing Details : 10pcs/Carton; Carton Size: 39.5*38.5*26cm

Display : Large LCD display

Accuracy : 0.05% accuracy

Contact Now

LCD Display Multifunction Process Calibrator

VICTOR 04S Temperature calibrator Voltage/mA Source multifunction Input and Source calibrator Large LCD display with 0.05% accuracy

I. Basic characteristics of the product

  • Analog output characteristics
  • Basic functions

DC voltage DCV, DC current DCI

  • The maximum output accuracy is 0.05% and the output display is 5 digits.
  • Output settings can be manually increased or decreased by position.
  • DCI output includes active output (internal 24V power supply), and passive output (external 24V power supply).
  • mA is equipped with the percentage display mode.
  • Upon DCI output, manual stepping and automatic waveform output functions may be available.

Manual step output includes: 25% stepping and 100% stepping.

Output current 0-20mA or 4~20mA is optional.

Automatic waveform output includes: automatic stepping, sawtooth wave and triangular wave and the automatic waveform operation parameters can be configured.

  • Internal 24V loop power is provided.
  • Maintenance setup function, including:

Auto power-off, backlight, flashlight

  • Others
  • The segment code is displayed on an LCD with a white backlight.
  • It has a LED flashlight for lighting.
  • It is powered by 3 AA battery cells. The battery compartment door is convenient for battery replacement. Low-battery detection is available.
  • It is small, firm, reliable, suitable for field use, and cheap.
  • User-optional large-suction magnetic sling is provided.

II. Basic function and performance of the product (technical index)

Analog output function [Used within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+% reading)]

Output function Range Output range Resolution Accuracy Remarks

DC voltage

DCV

10V -1.000V-11.000V 0.001V 0.05%+2mV Maximum output current: 5mA

DC current

DCI

30mA 0.000mA-30.000mA 0.001mA 0.05%+4uA

At 20 mA, the maximum load is 1000Ω

Upon transmitter simulation, the external loop power supply is 5-28V

Other characteristics:

  • Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Maximum applied voltage at input end: about 30Vpk; Maximum applied current at input end: about 25mA
  • Load characteristics: capacitive load ≥0.01uF (DCV/OHM/TC/RTD/FREQ); Inductive load ≥ 0.01uF 100uH (DCA)

Output load affects DCmV (0.001% full scale + 1nV)/mA; DCV (0.001% full scale + 1nV)/mA

  • The temperature range of internal temperature compensated sensor RJC is -10 to 50C. The temperature measurement accuracy at 18 to 28C is ±0.5C, and the temperature measurement accuracy at other temperature is ±1C. Cold end compensation time is 10S/ times.
  • Temperature coefficient: 0.1 × basic accuracy/℃ (temperature range < 18℃ or > 28℃)

  • Coefficient: 0.1 × basic accuracy/℃ (temperature range: <18℃ or >28℃)

III. General characteristics of the product

  • Operating temperature and humidity: 0 to 50ºC ≤80%RH without condensation; 40 to 50ºC ≤70%RH.
  • Storage temperature and humidity: -25 to 60ºC ≤90%RH without condensation.
  • Electrical safety: EN61010-1:2001

Withstand voltage: AC3540V(50/60Hz)/5 seconds between terminal and housing.

Insulation impedance: DC1000V/100MΩ or more between terminal and housing.

  • Electromagnetic compatibility (EMC): EN61326-1:2006

Performance criterion 2 is met, i.e. the function and performance are temporarily reduced or lost, but can be recovered by themselves.

  • Protection grade IP40.
  • Vibration and fall: IEC 60068-2-64:2008, IEC 60068-2-32:2008
  • Random, 2g, 5-500Hz; 1m drop test.
  • CE certification.
  • Quality standard: developed, designed and manufactured in accordance with TUV ISO 9001.
  • Calibration period and preheating time:

To ensure the accuracy of the Table, the calibration period is one year.

The startup preheating time is more than 30 minutes.

  • Instrument display and key

Segment code LCD display, white backlight

Rubber key is adopted

  • Instrument power supply

3 pcs of AA alkaline batteries for power supply

  • Dimension and weight

IV. Peripheral configuration of the product

  • Standard configuration

Industrial test conductor: 1 pair

User’s Manual: 1 manual

AA alkaline battery: 3 pcs

Graphic carton: 1 item

Fuse: 2 items


VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrratorVICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrratorVICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrratorVICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrratorVICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrratorVICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrratorVICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrrator


Product Tags:

LCD Display Multifunction Process Calibrator

      

0.05% accuracy Multifunction Process Calibrator

      

24V Multifunction Process Calibrator

      
China VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrrator wholesale

VICTOR 04S Voltage/mA Source calibrator tester Temperature calibrator simulator source transmitter calibrrator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: XI'AN BEICHENG ELECTRONICS CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)